FLUORESCENT LABELING & CONJUGATION

Fluorescent Labeling & Conjugation

Fluorescent-labeling projects for antibodies, fragments and recombinant proteins, from sample assessment and dye selection through conjugation, purification and agreed basic quality checks.

SERVICE BOUNDARYThis page describes the project workflow and assessable capabilities. It does not prescribe sample amount, timing or fixed quality tests; the formal scope is defined by technical assessment and project confirmation.
ENGAGEMENT MODE

Two ways to start a project

Label customer-supplied material, or begin by assessing confirmed StellaCyte material or a development candidate.

01CUSTOMER-SUPPLIED MATERIAL

Customer-supplied antibody or protein

Submit the sample type, amount, concentration, buffer and application. Process and delivery boundaries are confirmed after feasibility assessment.

Submit sample information
02STELLACYTE MATERIAL

StellaCyte material or development candidate

Request a combination using available dyes, confirmed material or an antibody-development candidate. Expression, supply and labeling status are assessed separately.

View products and candidates
SERVICE SCOPE

Labeling projects available for assessment

Build practical service combinations around StellaCyte antibodies, recombinant proteins, fluorescent dyes and conjugation processes.

01 · ANTIBODY

Fluorescent antibody labeling

Single-color labeling of research-grade IgG and biosimilar antibodies for flow cytometry, imaging and binding analysis.

UV421 · SF488 · SF594 · PE · APC · other options by assessment
02 · FRAGMENT

Antibody fragments and recombinant antibodies

Assess the labeling route from molecular structure, available reactive sites and downstream application, with recovery and risks confirmed before project initiation.

Fab / F(ab')₂ · Recombinant antibody
03 · PROTEIN

Fluorescent labeling of recombinant proteins

Protein labeling for tracking, binding, internalization and cell analysis, with sample amount and buffer assessed against protein properties.

Sample composition and buffer · project assessment
04 · OTHER

Biotin and other small-molecule conjugation

Discuss biotinylation or other custom conjugation after functional-group and process-feasibility review.

NHS · Maleimide · Other chemistry
PROJECT WORKFLOW

Five steps from sample to delivery

Each step includes a confirmation point so inputs, risks and delivery boundaries are clear before experimental work begins.

  1. 01

    Request and sample assessment

    Application, sample type, amount, purity and buffer system

  2. 02

    Dye and process selection

    Recommendation based on instrument channels, target abundance and reactive sites

  3. 03

    Conjugation reaction

    Small-scale or project-scale labeling under the confirmed plan

  4. 04

    Purification and basic quality checks

    Remove free dye and complete the agreed basic assessments

  5. 05

    Delivery and technical record

    Deliver material, a results summary and agreed project records

SAMPLE GUIDE

Sample information needed for assessment

Sample amount and concentration
Provide the available amount and concentration for assessment against the molecule and process
Purity and analytical method
Provide available purity results and the analytical method used
Buffer system
Disclose amines, sodium azide, glycerol, salts, reducing agents and other components
Sample details
Molecular type, molecular weight, application and storage conditions
Requested timing
Provide the requested window; the project schedule is confirmed after assessment
PROJECT LEVELS

Choose the engagement depth by project maturity

This is a discussion framework, not a fixed package. Actual work depends on sample properties and intended use.

FEASIBILITY

Feasibility assessment

For projects with incomplete sample conditions that need an initial reaction-route and risk assessment.

  • Sample and buffer review
  • Reactive-site and dye recommendation
  • Risk and missing-information list
STANDARD

Standard labeling project

For research projects with a clear target label and application that can use an established process route.

  • Plan confirmation and conjugation
  • Free-dye removal
  • Agreed basic-results summary
CUSTOM

Custom process project

For special molecular formats, labels, recovery targets or analytical requirements that need dedicated development.

  • Process-condition exploration
  • Purification and analytical-method alignment
  • Stage results and delivery confirmation
BUFFER REVIEW

Buffer pre-check

Conjugation chemistries have different constraints. The following supports sample-submission discussion and is not an unevaluated operating protocol.

View the sample and buffer guide
Component or informationAssessment noteRecommended action
Protein concentration and total volumeDetermines reaction scale, recovery assessment and analytical methodRequired
Amine-containing components such as Tris or glycineMay interfere with some NHS reaction routesDisclose and assess buffer exchange
Carrier proteins such as BSA or gelatinMay react with the target molecule or affect quantificationRemoval usually recommended
Sodium azide, glycerol and salt concentrationMay affect process, purification or downstream useDisclose fully
Reducing agents such as DTT or TCEPMay affect thiol or protein-structure-related routesRequired disclosure
Molecular weight, purity and storage conditionsUsed to select purification and assess sample stabilityRequired
START A PROJECT

Tell us about the sample, requested label and application

You can submit the information currently available. The technical team will identify additional sample and process details needed for assessment.

Submit a labeling request