Commonly placed on a 405 nm violet-laser channel.
PE, APC and BV421 antibody conjugation
Choose a fluorophore from the instrument, antigen and full panel—not from brightness alone. This guide frames the questions used to assess PE-, APC- and BV421-labeled antibody projects for flow cytometry.
Commonly assigned to a 561 nm yellow-green-laser channel.
Commonly assigned to a 640 nm red-laser channel.
Three labels, three different panel roles
The right label depends on co-expression, detector availability, background, fixation and the importance of the marker in the gating strategy.
Reserve signal for the difficult marker
Consider antigen abundance and biological separation before assigning a high-priority fluorophore. A low-abundance or dimly separated marker usually needs more panel attention than a strongly expressed lineage marker.
Check co-expression and spread
Markers expressed on the same cells can make spillover and spreading error more important. Review the entire panel and detector layout rather than evaluating one conjugate in isolation.
Confirm processing conditions
Fixation, permeabilization, sample autofluorescence and storage can affect the practical result. State the complete workflow when requesting a labeling assessment.
Compare the factors before choosing
What we need to recommend PE, APC or BV421
A useful recommendation starts with the assay rather than a dye name alone.
- 01
Instrument
Instrument model, installed lasers, detector filters and any fixed panel constraints.
- 02
Biology
Target, expected expression, sample species and cell type, including important co-expression patterns.
- 03
Antibody
Molecular format, amount, concentration, purity and buffer components for the supplied material.
- 04
Workflow
Surface or intracellular staining, fixation/permeabilization, controls and intended sample handling.
Related conjugates and controls
Use matched isotype controls where scientifically appropriate, or start a custom project for a customer-supplied antibody.
Custom fluorescent antibody conjugation
Customer-supplied or StellaCyte research material
PE, APC, BV421 and other labels by assessmentView details 12 IN-STOCK CONTROLSRecombinant isotype control antibodies
Mouse and human isotype controls
Pure and 14 selectable flow-cytometry conjugationsView details FLOW ANTIBODIESFlow cytometry antibody catalog
Search by target, clone or fluorophore
Browse BV421, PE, APC and other configurationsView detailsQuestions researchers ask before starting
Can you conjugate a customer-supplied antibody to PE, APC or BV421?
Customer-supplied research antibodies can be assessed for custom labeling. Feasibility depends on amount, concentration, purity, buffer composition, molecular format and the requested downstream application.
Which label is best for a low-expression target?
There is no universal answer from target abundance alone. Instrument optics, background, co-expression, panel spread and processing conditions must be considered together.
Do you accept antibodies containing BSA, azide or amine buffers?
Disclose all additives during assessment. Carrier proteins and some buffer components may interfere with a labeling route or quantification and may require buffer exchange or other preparation.
Is a fixed dye-to-antibody ratio guaranteed?
No fixed ratio is implied by this guide. Target labeling range, analytical method and acceptance criteria are confirmed for the individual project before experimental work begins.
Send the antibody, panel and instrument context
We will review the sample and recommend a practical labeling route, required preparation and project-specific confirmation points.