FLUOROPHORE SELECTION GUIDE

PE, APC and BV421 antibody conjugation

Choose a fluorophore from the instrument, antigen and full panel—not from brightness alone. This guide frames the questions used to assess PE-, APC- and BV421-labeled antibody projects for flow cytometry.

VIOLET-LASER OPTIONBV421

Commonly placed on a 405 nm violet-laser channel.

YELLOW-GREEN OPTIONPE

Commonly assigned to a 561 nm yellow-green-laser channel.

RED-LASER OPTIONAPC

Commonly assigned to a 640 nm red-laser channel.

START WITH THE PANEL

Three labels, three different panel roles

The right label depends on co-expression, detector availability, background, fixation and the importance of the marker in the gating strategy.

01

Reserve signal for the difficult marker

Consider antigen abundance and biological separation before assigning a high-priority fluorophore. A low-abundance or dimly separated marker usually needs more panel attention than a strongly expressed lineage marker.

02

Check co-expression and spread

Markers expressed on the same cells can make spillover and spreading error more important. Review the entire panel and detector layout rather than evaluating one conjugate in isolation.

03

Confirm processing conditions

Fixation, permeabilization, sample autofluorescence and storage can affect the practical result. State the complete workflow when requesting a labeling assessment.

DECISION TABLE

Compare the factors before choosing

LabelTypical laserUseful discussion pointConfirm before labeling
BV421405 nmViolet-channel placement and separation from other violet-excited dyesInstalled filters, co-expressed markers and fixation workflow
PE561 nmPanel placement for markers that need clear population separationAutofluorescence, tandem-dye neighbors and sample processing
APC640 nmRed-laser placement with a relatively independent excitation pathRed-laser configuration, APC-family neighbors and storage conditions
PROJECT INPUTS

What we need to recommend PE, APC or BV421

A useful recommendation starts with the assay rather than a dye name alone.

  1. 01

    Instrument

    Instrument model, installed lasers, detector filters and any fixed panel constraints.

  2. 02

    Biology

    Target, expected expression, sample species and cell type, including important co-expression patterns.

  3. 03

    Antibody

    Molecular format, amount, concentration, purity and buffer components for the supplied material.

  4. 04

    Workflow

    Surface or intracellular staining, fixation/permeabilization, controls and intended sample handling.

RELATED PRODUCTS & SERVICES

Related conjugates and controls

Use matched isotype controls where scientifically appropriate, or start a custom project for a customer-supplied antibody.

CUSTOM SERVICE

Custom fluorescent antibody conjugation

Customer-supplied or StellaCyte research material

PE, APC, BV421 and other labels by assessmentView details
12 IN-STOCK CONTROLS

Recombinant isotype control antibodies

Mouse and human isotype controls

Pure and 14 selectable flow-cytometry conjugationsView details
FLOW ANTIBODIES

Flow cytometry antibody catalog

Search by target, clone or fluorophore

Browse BV421, PE, APC and other configurationsView details
FREQUENTLY ASKED QUESTIONS

Questions researchers ask before starting

Can you conjugate a customer-supplied antibody to PE, APC or BV421?

Customer-supplied research antibodies can be assessed for custom labeling. Feasibility depends on amount, concentration, purity, buffer composition, molecular format and the requested downstream application.

Which label is best for a low-expression target?

There is no universal answer from target abundance alone. Instrument optics, background, co-expression, panel spread and processing conditions must be considered together.

Do you accept antibodies containing BSA, azide or amine buffers?

Disclose all additives during assessment. Carrier proteins and some buffer components may interfere with a labeling route or quantification and may require buffer exchange or other preparation.

Is a fixed dye-to-antibody ratio guaranteed?

No fixed ratio is implied by this guide. Target labeling range, analytical method and acceptance criteria are confirmed for the individual project before experimental work begins.

NEXT STEP

Send the antibody, panel and instrument context

We will review the sample and recommend a practical labeling route, required preparation and project-specific confirmation points.

Request PE / APC / BV421 assessment