FLOW CYTOMETRY SELECTION GUIDE

Anti-PD-1 antibodies for flow cytometry

Select an anti-PD-1 flow antibody by target identity, sample species, clone, format, fluorophore and the biological question. Browse relevant StellaCyte configurations and plan controls before fixing the panel.

TARGETPD-1

Also recorded as PDCD1 and CD279.

APPLICATIONFlow

Surface-staining context should be confirmed for the selected product.

CONFIGURATIONMulti-color

Choose the conjugate in the context of the complete panel.

SELECTION LOGIC

Start with the biological comparison

PD-1 signal is meaningful only when sample handling, comparison groups and gating context are defined.

01

Define the sample and comparison

Record species, tissue or cell source, stimulation state and the biological groups being compared. These factors affect both expected PD-1 distribution and the controls needed for interpretation.

02

Confirm clone and reactivity

Use the exact clone, host and species-reactivity information of the selected record. Do not assume that similarly named anti-PD-1 antibodies are interchangeable.

03

Place PD-1 in the panel

Review expected expression, co-expressed markers and the gating role of PD-1 before choosing BV421, PE, APC or another configuration.

DECISION TABLE

Compare the factors before choosing

DecisionWhat to recordWhy it mattersPractical next step
Target identityPD-1 / PDCD1 / CD279Prevents confusion with ligand or pathway-related reagentsSearch using target aliases and verify the product record
Biological sampleSpecies, cell type, tissue and stimulationSets the expected positive and negative populationsDefine biological comparison controls before staining
Antibody configurationClone, format and conjugateAffects panel placement and product-specific useReview the exact configuration rather than the target name alone
Panel contextLasers, filters and co-expressed markersDetermines spillover and population separationUse a panel-level review and titrate the selected antibody
EXPERIMENT PLAN

A practical PD-1 flow-cytometry workflow

The final method should be established experimentally for the selected product and sample.

  1. 01

    Define populations

    Specify the parent population, expected PD-1-positive comparison and biological negative or lower-expression comparison.

  2. 02

    Choose controls

    Plan unstained, single-stain compensation and FMO controls as needed; use an isotype control only for a defined experimental purpose.

  3. 03

    Titrate

    Determine a suitable staining concentration for the exact clone, conjugate, sample and instrument instead of transferring a condition without verification.

  4. 04

    Document

    Record sample processing, staining conditions, instrument configuration and gating strategy with the result.

RELATED PRODUCTS & SERVICES

Relevant anti-PD-1 flow antibodies

These links come from the public StellaCyte flow-cytometry catalog. Confirm the exact clone, format, conjugate and validation status on each product page.

SC-FC-0004

PD-1 Antibody, anti-human, Recombinant

PD-1 · Human

Clone SHR0004 · Pure / BV421 / PE / APCView details
SC-FCA-00006

PD-1 Antibody, anti-human, Recombinant

PD-1 · Human

Clone SCY-0006 · Pure / BV421 / PE / APCView details
SC-FCA-00010

PD-1 Antibody, anti-human, Recombinant

PD-1 · Human

Clone SCY-0010 · Pure / BV421 / PE / APCView details
SC-FCA-00053

PD-1 Antibody, anti-human, Recombinant

PD-1 · Human

Clone SCY-0053 · Pure / BV421 / PE / APCView details
SC-FCA-00055

PD-1 Antibody, anti-human, Recombinant

PD-1 · Human

Clone SCY-0055 · Pure / BV421 / PE / APCView details
SC-FCA-00077

PD-1 Antibody, anti-human, Recombinant

PD-1 · Human

Clone SCY-0077 · Pure / BV421 / PE / APCView details
FREQUENTLY ASKED QUESTIONS

Questions researchers ask before starting

Is PD-1 the same target as PDCD1 and CD279?

PD-1 is the commonly used protein name, PDCD1 is the gene symbol and CD279 is the CD designation. Product identity should still be checked at the individual record level.

Which fluorophore should I choose for anti-PD-1?

Choose the conjugate after reviewing expected expression, co-expression, instrument lasers and filters, sample autofluorescence and the importance of PD-1 in the gating strategy.

Do I need an isotype control for PD-1 flow cytometry?

An isotype control can address defined nonspecific-binding questions, but it does not replace biological controls, FMO controls, compensation controls or antibody titration.

Can StellaCyte prepare another anti-PD-1 conjugate?

Custom conjugation can be assessed for suitable StellaCyte or customer-supplied research material. The requested fluorophore, antibody properties and panel context should be submitted for review.

NEXT STEP

Need a PD-1 configuration for an existing panel?

Send the sample, instrument and current marker list so the technical team can review product and conjugate options in context.

Request PD-1 panel support